At FA Stop

*Use the meter wrench to loosen the house side spud nut, creating a leak to check flow *If the register sweep hand does not move or the leak indicator does not show movement or the numbers show no progressive movement, the meter is stopped and must be replaced. *Inspect the water meter service for backflow devices. *If no backflow device is found, use hand pump to keep the water level below the

house side spuds. *Remove meter. *Test Dual Check for functionality-Report if broken. *Replace the meter, gaskets, and antenna. *Verify the flow arrow on the meter points to the house side spud nut.

*Verify meter lid is clean and clear of obstruction