Unified Development Ordinance, 33rd Supplement, August 2024
Article 3.2. Base Dimensional Standards | CHAPTER 3. MIXED USE DISTRICTS
Sec. 3.2.6. Mixed Use Building
A4
F2 F2
D1
Alley
Alley
A1/A2
F1
C3
E2 E1 E2
C5
B4
B3
F3
Building Setbacks
A3
C2
Primary Street
Primary Street
C1
Parking Setbacks
B2
B1
Side Street
Side Street
OP-, OX- NX-, CX-, IX-
OP-, OX- NX-, CX-, IX-
DX
DX
A. Lot Dimensions A1 Area (min)
D. Height D1 Principal building (max) D2 Accessory structure (max)
n/a
n/a n/a n/a
Set by district
Set by district
A2 Area (max) A3 Width (min)
10 acres (NX- only)
26'
26'
E. Floor Heights E1 Ground story height, floor to floor (min) E2 Upper story height, floor to floor (min)
n/a
13’
15’
10%
10%
A4 Outdoor amenity area (min) B. Building/Structure Setbacks B1 From primary street (min)
9’
9’
F. Transparency F1
5' 5'
3' 3'
Ground story (min) Upper story (min) Blank wall (max)
50% 20%
66% 20%
B2 From side street (min) B3 From side lot line (min) B4 From rear lot line (min) C. Parking Setbacks C1 From primary street (min) C2 From side street (min) C3 From side lot line (min) C4 From rear lot line (min) B5 From alley
F2 F3
0' or 6' 0' or 6'
0' or 6' 0’or 6’
20’
20’
5’
5’
See Sec. 1.5.4.D “Building Setbacks” for specific building element requirements.
10' 10'
10' 10'
0' or 3' 0' or 3'
0' or 3' 0' or 3'
C5 From alley (min)
5'
5'
3 – 9 Published August 2024
Part 10: Unified Development Ordinance City of Raleigh, North Carolina
Supp. No. 33
Made with FlippingBook. PDF to flipbook with ease