Unified Development Ordinance, 31st Supplement, May 2024
CHAPTER 7. GENERAL DEVELOPMENT STANDARDS | Article 7.2. Landscaping and Screening
4. Berms Where allowed, a berm in a protective yard must meet the following. a. A berm cannot be built in any protective yard whenever the protective yard is also a tree conservation area. b. Berms shall have a minimum average height of 3 feet, measured perpendicular to the center of the crown.
c. The berm must contain a rounded crown suitable for planting and a stabilized side slope of no greater than three-to-one. A steeper side slope may be used in exceptional cases when all of the following are met: i. This steeper slope is sufficiently stabilized; and ii. Physical constraints of the site prevent the use of a flatter slope. d. The berm shall be planted with ¾ of the required number of shrubs.
6.5 ’
5’
3.5 ’
100’
100’
100’
15’ Type C2
10’ Type C1
100’
10’ Type C3
Type C4 35’
Type C1
Type C2
Type C3
Type C4
Width (avg. min) Fence Height (min)
10'
15'
10'
35'
6.5'
Not required
Not required
Not required
In lieu of planting shrubs, a 3.5' wall may be installed
Wall Height (min)
6.5'
Not required
Not required
Shade Trees (min per 100') Understory Trees (min per 100')
Not required Not required
4
Not required Not required
Not required Not required Not required Not required
Not required
Shrubs (min per 100') Shrub Height (min)
30
15
30
3'
5'
3.5'
A berm in accordance with Sec. 7.2.4.D.4. may be installed, unless otherwise required. The installation shall not alter the yard width and shade tree requirements
A berm shall be installed in accordance with Sec. 7.2.4.D.4. except the minimum height of the berm shall be 10’ measured perpendicular to the crown
Berm
Not allowed
Not allowed
Supp. No. 31
7 – 16 Published May 2024
Part 10: Unified Development Ordinance City of Raleigh, North Carolina
Made with FlippingBook Learn more on our blog