Unified Development Ordinance, 31st Supplement, May 2024
Article 3.2. Base Dimensional Standards | CHAPTER 3. MIXED USE DISTRICTS
Sec. 3.2.4. Apartment
A4
Alley
Alley
D1
A1/A2
D2
C3
E3
C4
E2 E2 E1
B4
B3
Building Setbacks
A3
C2
Primary Street
Primary Street
Parking Setbacks
C1
B2
B1
Side Street
Side Street
RX-, OX-, NX-, CX-
DX
RX-, OX-, NX-, CX-
DX
D. Height D1 Principal building (max) D2 Accessory structure (max)
A. Lot Dimensions A1 Area (min)
Set by district
Set by district
7,500 sf
n/a n/a n/a
26'
26'
A2 Area (max) A3 Width (min)
10 acres (NX- only)
n/a
E. Transparency E1 Ground story (min) E2 Upper story (min) E3 Blank wall (max)
10%
A4 Outdoor amenity area (min) B. Building/Structure Setbacks B1 From primary street (min) B2 From side street (min) B3 From side lot line (min) B4 From rear lot line (min) C. Parking Setbacks C1 From primary street (min) C2 From side street (min) C3 From side lot line (min) C4 From rear lot line (min) C5 From alley, garage only (min) B5 From alley i
10%
20% 15%
20% 15%
5' 5'
5' 5'
35'
35'
See Sec. 1.5.4.D “Building Setbacks” for specific building elements requirements
0' or 6' 0' or 6'
0' or 6' 0’ or 6’
i Garages (or a portion thereof) must either be located 4 feet from the travel lane of an alley or rear access drive or be a minimum of 20 feet from the alley or rear access drive. Where parking spaces are located between the garage and the alley or rear access drive, the garage must be located at least 20 feet from the travel lane of an alley or rear access drive.
4' or 20' min
4' or 20' min
10' 10'
10' 10'
0' 0' 4'
0' 0' 4'
3 – 7 Published May 2024
Part 10: Unified Development Ordinance City of Raleigh, North Carolina
Supp. No. 31